Scanning range<\/strong>\n10% reflectivity<\/p><\/td>\n
\n 8 m<\/p><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n Mechanics and electronics<\/h3>\n\n\n\nConnection type<\/strong><\/td>\n1 x Ethernet connection, 4-pin M12 female connector\n 1 x connection power \/ synchronisation output 5-pin, M12 male connector<\/p>\n 1 x Micro USB female connector, type B<\/p><\/td>\n<\/tr>\n | \nSupply voltage<\/strong><\/td>\n9 V DC – 28 V DC<\/td>\n<\/tr>\n | \nPower consumption<\/strong><\/td>\nTyp. 4 W<\/td>\n<\/tr>\n | \nHousing colour <\/strong><\/td>\nGrey (RAL 7032)<\/td>\n<\/tr>\n | \nEnclosure rating<\/strong><\/td>\nIP67 – applies only when the plastic cover of the aux interface is closed (IEC 60529:1989+AMD1:1999+AMD2:2013)<\/td>\n<\/tr>\n | \nProtection class<\/strong><\/td>\nIII (IEC 61140:2016-1)<\/td>\n<\/tr>\n | \nWeight<\/strong><\/td>\n250 g, without connecting cables<\/td>\n<\/tr>\n | \nDimensions<\/strong><\/td>\n6 x 6 x 8.6 cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\nPerformance<\/h3>\n\n\n\nResponse time<\/strong><\/td>\n1 x scan, typ. 67 ms\n 2 x scans, ≤ 134 ms (at +45° to +225° of the working range; max. 150 ms at –45° to +45° of the working range)<\/p><\/td>\n<\/tr>\n | \nSystematic error<\/strong><\/td>\n± 60 mm (typical value at 90% reflectivity up to maximum scanning range- real value depends on ambient conditions)<\/td>\n<\/tr>\n | \nStatistical error<\/strong><\/td>\n< 20 mm (typical value at 90% reflectivity up to maximum scanning range- real value depends on ambient conditions)<\/td>\n<\/tr>\n | \nIntegrated application<\/strong><\/td>\nOutput of measurement data<\/td>\n<\/tr>\n | \nDetectable object shape<\/strong><\/td>\nAlmost any<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\nInterfaces<\/h3>\n\n\n\nEthernet<\/strong><\/td>\nTCP \/ IP<\/td>\n<\/tr>\n | \nUSB<\/strong>\n Remark<\/p>\n Function<\/p><\/td>\n \n Micro USB<\/p>\n AUX, parameterisation<\/p><\/td>\n<\/tr>\n | \nDigital inputs<\/strong><\/td>\n0<\/td>\n<\/tr>\n | \nDigital outputs<\/strong><\/td>\n1 (PNP, sync \/ device ready)<\/td>\n<\/tr>\n | \nOptical indicators<\/strong><\/td>\n2 x LEDs (ON, switching status)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\nAmbient data<\/h3>\n\n\n\nObject reflectivity<\/strong><\/td>\n4% – 1000% (reflector)<\/td>\n<\/tr>\n | \nElectromagnetic compatibility<\/strong>\n Emitted radiation<\/p>\n Electromagnetic immunity<\/p><\/td>\n \n Residential area (EN 61000-6-3:2007+AMD:A1:2011)<\/p>\n Industrial environment (EN 61000-6-2:2005)<\/p><\/td>\n<\/tr>\n | \nVibration resistance<\/strong>\n Sine resonance scan<\/p>\n Sine test<\/p>\n Noise test<\/p><\/td>\n \n 10 Hz – 1,000 Hz (IEC 60068-2-6:2007)<\/p>\n 10 Hz – 500 Hz, 5 g, 10 frequency cycles (IEC 60068-2-6:2007)<\/p>\n 10 Hz – 250 Hz, 4.24 g RMS, 5 h (IEC 60068-2-64:2008)<\/p><\/td>\n<\/tr>\n | \nShock resistance <\/strong><\/td>\n50 g, 11 ms, ± 3 single shocks \/ axis (IEC 60068-2-27:2008)\n 25 g, 6 ms, ± 1,000 continuous shocks \/ axis (IEC 60068-2-27:2008)<\/p>\n 50 g, 3 ms, ± 5,000 continuous shocks \/ axis (IEC 60068-2-27:2008)<\/p><\/td>\n<\/tr>\n | \nAmbient operating temperature <\/strong><\/td>\n-25 °C – +50 °C (IEC 60068-2-14:2009)<\/td>\n<\/tr>\n | \nStorage temperature<\/strong><\/td>\n-40 °C – +75 °C (IEC 60068-2-14:2009)<\/td>\n<\/tr>\n | \nSwitch-on temperature<\/strong><\/td>\n-10 °C – +50 °C<\/td>\n<\/tr>\n | \nTemperature change<\/strong><\/td>\n-25 °C – +50 °C, 10 cycles (EN 60068-2-14:2009)<\/td>\n<\/tr>\n | \nDamp heat<\/strong><\/td>\n25 °C – 55 °C, 95% rF, 6 cycles (EN 60068-2-30:2005)<\/td>\n<\/tr>\n | \nPermissable relative humidity<\/strong>\n Operation<\/p>\n Storage<\/p><\/td>\n \n < 80%, non-condensing (EN 60068-2-30:2005)<\/p>\n ≤ 95%, non-condensing (EN 60068-2-30:2005)<\/p><\/td>\n<\/tr>\n | \nAmbient light immunity<\/strong><\/td>\n80,000 lx<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":" The flexible, highly accurate TiM581 2D LiDAR sensor is a non-contact ranging solution with a 25-metre maximum reach and angular resolution of 0.33\u00b0, enabling precise measurement and monitoring within the scanning field. HDDM+ technology means that a 1,470 m\u00b2 outdoor area can be reliably scanned regardless of surface or ambient light.<\/p>\n Its compact form factor and IP67 rated industrial-strength design make it ideal for integration with small mobile platforms and AGVs, detecting sufficient properties based on landmarks in the environment to localise the vehicle.<\/p>\n TiM581 outputs measurement data for each individual angle as a machine-readable data string (ASCII or binary).\u00a0 All data \u2013 including object distance and signal strength \u2013 is relayed via USB or Ethernet interface, which can be visualised in SOPAS or imported into your specific application.<\/p>\n","protected":false},"featured_media":62665,"template":"","meta":{"_acf_changed":false,"content-type":""},"product_cat":[201,351],"product_tag":[423],"acf":[],"yoast_head":"\n SICK TiM581 2D LiDAR sensor - outdoor<\/title>\n\n\n\n\n\n\n\n\n\n\n\n\n\t\n\t\n\t\n\n\n\n\n\n\t\n | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |